Flæðismælingar með ómskoðun og í hjartaþræðingu : mat á blóðflæði um op á milli gátta

2.50
Hdl Handle:
http://hdl.handle.net/2336/87758
Title:
Flæðismælingar með ómskoðun og í hjartaþræðingu : mat á blóðflæði um op á milli gátta
Authors:
Hróðmar Helgason; Kristján Eyjólfsson
Citation:
Læknablaðið 1991, 77(9):337-41
Issue Date:
1-Nov-1991
Abstract:
Twelve patients with left-to-right shunt at the atrial level (11 with atrial septal defect (ASD) and one with partial anomalous pulmonary venous connection (PAPVC)) underwent diagnostic cardiac catheterization (cath) after quantification of the shunt had been estimated using Doppler technique. The pulmonary blood flow and the systemic blood flow was measured during the cath using the Fick method. The results of the Doppler technique and the cath method were compared. The pulmonary blood flow (Qp) by Doppler ranged from 4.4 - 9.3 (median 6.7) l/min/m2 and 4.1 -8.9 (median 6.7) l/min/m2 by the Fick method. Correlation (Spearman rank): r = 0.85 and p < 0.01. The systemic blood flow (Qs) using Doppler ranged from 2.6 - 4.8 (median 3.8) l/min/m2 and 3.0-5.1 (median 3.7) l/min/m2 by the Fick method. Correlation: r = 0.87, p < 0.01. When Qp/Qs ratio using these two methods was compared the r = 0.83, p < 0.01. We conclude that the Doppler method is an effective and reliable method of measuring the size of left-to-right shunt at the atrial level is this group of patients.; Mæling á flæði með Dopplerómun er rannsóknaraðferð sem hefur mikilvægt klínískt notagildi. Hefur verið sýnt fram á það á ýmsan hátt, í dýratilraunum, við mælingar á heilbrigðum sjálfboðaliðum og við klínískar rannsóknir á sjúklingum (1-4). Þannig var sýnt fram á, að flæðismæling með Dopplerómun væri sambærileg við aðrar aðferðir sem beita má við mælingar flæðis, þegar útfall hjartans var mælt hjá börnum (5). Í sjúklingum með meðfædda hjartagalla er hlutfallið á milli flæðis til lungna og flæðis um ósæð til líkamans (Qp:Qs) notað þegar ákvörðun er tekin um aðgerð. Sambærilegar niðurstöður fást með Dopplerómun og í hjartaþræðingu þegar þetta hlutfall er mælt (6). Tilgangur rannsóknarinnar var að mæla blóðflæði frá hjarta, bæði með Dopplerómun og í hjartaþræðingu og athuga fylgni þessara tveggja aðferða. Einnig er mælt magn framhjáhlaups (shunt) yíir op á milli gátta. Þá var athugað hvort Dopplerómun sé nothæf aðferð til að taka ákvörðun um aðgerð hjá sjúklingum með op á milli gátta (Atrial septal defect, ASD), án þess að sjúklingurinn gangist undir hjartaþræðingu.
Description:
Neðst á síðunni er hægt að nálgast greinina í heild sinni með því að smella á hlekkinn Skoða/Opna(view/open)
Additional Links:
http://www.laeknabladid.is

Full metadata record

DC FieldValue Language
dc.contributor.authorHróðmar Helgasonen
dc.contributor.authorKristján Eyjólfssonen
dc.date.accessioned2009-12-10T13:52:41Z-
dc.date.available2009-12-10T13:52:41Z-
dc.date.issued1991-11-01-
dc.date.submitted2009-12-10-
dc.identifier.citationLæknablaðið 1991, 77(9):337-41en
dc.identifier.issn0023-7213-
dc.identifier.urihttp://hdl.handle.net/2336/87758-
dc.descriptionNeðst á síðunni er hægt að nálgast greinina í heild sinni með því að smella á hlekkinn Skoða/Opna(view/open)en
dc.description.abstractTwelve patients with left-to-right shunt at the atrial level (11 with atrial septal defect (ASD) and one with partial anomalous pulmonary venous connection (PAPVC)) underwent diagnostic cardiac catheterization (cath) after quantification of the shunt had been estimated using Doppler technique. The pulmonary blood flow and the systemic blood flow was measured during the cath using the Fick method. The results of the Doppler technique and the cath method were compared. The pulmonary blood flow (Qp) by Doppler ranged from 4.4 - 9.3 (median 6.7) l/min/m2 and 4.1 -8.9 (median 6.7) l/min/m2 by the Fick method. Correlation (Spearman rank): r = 0.85 and p < 0.01. The systemic blood flow (Qs) using Doppler ranged from 2.6 - 4.8 (median 3.8) l/min/m2 and 3.0-5.1 (median 3.7) l/min/m2 by the Fick method. Correlation: r = 0.87, p < 0.01. When Qp/Qs ratio using these two methods was compared the r = 0.83, p < 0.01. We conclude that the Doppler method is an effective and reliable method of measuring the size of left-to-right shunt at the atrial level is this group of patients.en
dc.description.abstractMæling á flæði með Dopplerómun er rannsóknaraðferð sem hefur mikilvægt klínískt notagildi. Hefur verið sýnt fram á það á ýmsan hátt, í dýratilraunum, við mælingar á heilbrigðum sjálfboðaliðum og við klínískar rannsóknir á sjúklingum (1-4). Þannig var sýnt fram á, að flæðismæling með Dopplerómun væri sambærileg við aðrar aðferðir sem beita má við mælingar flæðis, þegar útfall hjartans var mælt hjá börnum (5). Í sjúklingum með meðfædda hjartagalla er hlutfallið á milli flæðis til lungna og flæðis um ósæð til líkamans (Qp:Qs) notað þegar ákvörðun er tekin um aðgerð. Sambærilegar niðurstöður fást með Dopplerómun og í hjartaþræðingu þegar þetta hlutfall er mælt (6). Tilgangur rannsóknarinnar var að mæla blóðflæði frá hjarta, bæði með Dopplerómun og í hjartaþræðingu og athuga fylgni þessara tveggja aðferða. Einnig er mælt magn framhjáhlaups (shunt) yíir op á milli gátta. Þá var athugað hvort Dopplerómun sé nothæf aðferð til að taka ákvörðun um aðgerð hjá sjúklingum með op á milli gátta (Atrial septal defect, ASD), án þess að sjúklingurinn gangist undir hjartaþræðingu.en
dc.language.isoisen
dc.publisherLæknafélag Íslands, Læknafélag Reykjavíkuren
dc.relation.urlhttp://www.laeknabladid.isen
dc.subject.meshBlood Flow Velocityen
dc.subject.meshEchocardiography, Doppleren
dc.subject.meshEchocardiographyen
dc.subject.meshUltrasonographyen
dc.titleFlæðismælingar með ómskoðun og í hjartaþræðingu : mat á blóðflæði um op á milli gáttais
dc.typeArticleen
dc.identifier.journalLæknablaðiðen
All Items in Hirsla are protected by copyright, with all rights reserved, unless otherwise indicated.