Matrix effects and the performance and selection of quality-control procedures to monitor PO2 measurements
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Issue Date
1996-03-01
Metadata
Show full item recordCitation
Clin. Chem. 1996, 42(3):392-6Abstract
We have assessed how variation in the matrix of control materials would affect error detection and false-rejection characteristics of quality-control (QC) procedures used to monitor PO2 in blood gas measurements. To determine the expected QC performance, we generated power curves for S(mat)/S(meas) ratios of 0.0-4.0. These curves were used to estimate the probabilities of rejecting analytical runs having medically important errors, calculated from the quality required by the CLIA '88 proficiency testing criterion and the precision and accuracy expected for a typical analytical system. When S(mat)/S(meas) ratios are low, the effects of matrix on QC performance are not serious, permitting selections of QC procedures based on simple power curves for a single component of variation. As S(mat)/S(meas) ratios increase, single-rule procedures generally show a loss in error detection, whereas multirule procedures, including the 3(1)s control rule, show an increase in false rejections. An optimized QC design is presented.Description
To access publisher full text version of this article. Please click on the hyperlink in Additional Links fieldAdditional Links
http://www.clinchem.org/cgi/content/abstract/42/3/392Collections
Related articles
- QC Validator 2.0: a computer program for automatic selection of statistical QC procedures for applications in healthcare laboratories.
- Authors: Westgard JO, Stein B, Westgard SA, Kennedy R
- Issue date: 1997 Jul
- New insight into the comparative power of quality-control rules that use control observations within a single analytical run.
- Authors: Parvin CA
- Issue date: 1993 Mar
- Selecting multi-rule quality control procedures based on patient risk.
- Authors: Bayat H
- Issue date: 2017 Oct 26
- An Analysis of Multirules for Monitoring Assay Quality Control.
- Authors: Walker BS, Pearson LN, Schmidt RL
- Issue date: 2020 Jan 2
- Design and evaluation of statistical control procedures: applications of a computer "quality control simulator" program.
- Authors: Westgard JO, Groth T
- Issue date: 1981 Sep