dc.description.abstractTo enable the investigation of fetal movement in a manner similar to fetal heart rate (FHR) monitoring we have developed an apparatus (the DopFet system) that consists of a pair of miniature sensors, a 2-MHz continuous-wave directional Doppler electronic module and a laptop personal computer. One of the sensors is aimed at the fetal limbs and the other at the thorax to detect heart and upper body movements. The signals are analyzed, presented in real-time and postprocessed by software developed by us. The postprocessing software computes a number of parameters (the DopFet parameters) describing fetal movement. These parameters can be divided into two categories: parameters that describe the quantity of fetal movement (i.e., number of movements) and parameters that describe qualitative aspects of fetal movement (i.e., average movement duration). Future studies using the DopFet system will be aimed at discovering which of these parameters or combination of parameters is the best indicator of fetal well-being. We present an example of a 0.5 h recording and the results of testing on 23 volunteer mothers. These results show good sensitivity of the system compared to real-time ultrasound (US). The system detects 96% of rolling movements, 100% of flexion movements and 97% of leg movements.
dc.language.isoenen
dc.publisherPergamon Pressen
dc.relation.urlhttp://dx.doi.org/10.1016/S0301-5629(00)00253-2en
dc.subject.meshFemaleen
dc.subject.meshFetal Movementen
dc.subject.meshHeart Rate, Fetalen
dc.subject.meshHumansen
dc.subject.meshImage Processing, Computer-Assisteden
dc.subject.meshPregnancyen
dc.subject.meshSensitivity and Specificityen
dc.subject.meshUltrasonography, Doppleren
dc.subject.meshUltrasonography, Prenatalen
dc.titleThe DopFet system: a new ultrasonic Doppler system for monitoring and characterization of fetal movementen
dc.typeArticleen
dc.contributor.departmentUniversity of Iceland, Reykjavík, Iceland. brynjark@rsp.isen
dc.identifier.journalUltrasound in medicine & biologyen
html.description.abstractTo enable the investigation of fetal movement in a manner similar to fetal heart rate (FHR) monitoring we have developed an apparatus (the DopFet system) that consists of a pair of miniature sensors, a 2-MHz continuous-wave directional Doppler electronic module and a laptop personal computer. One of the sensors is aimed at the fetal limbs and the other at the thorax to detect heart and upper body movements. The signals are analyzed, presented in real-time and postprocessed by software developed by us. The postprocessing software computes a number of parameters (the DopFet parameters) describing fetal movement. These parameters can be divided into two categories: parameters that describe the quantity of fetal movement (i.e., number of movements) and parameters that describe qualitative aspects of fetal movement (i.e., average movement duration). Future studies using the DopFet system will be aimed at discovering which of these parameters or combination of parameters is the best indicator of fetal well-being. We present an example of a 0.5 h recording and the results of testing on 23 volunteer mothers. These results show good sensitivity of the system compared to real-time ultrasound (US). The system detects 96% of rolling movements, 100% of flexion movements and 97% of leg movements.


Files in this item

Thumbnail
Name:
Publisher version

This item appears in the following Collection(s)

Show simple item record