Fundus imaging in newborn children with wide-field scanning laser ophthalmoscope
dc.contributor.author | Magnusdottir, Vigdis | |
dc.contributor.author | Vehmeijer, Wouter B. | |
dc.contributor.author | Eliasdottir, Thorunn S. | |
dc.contributor.author | Hardarson, Sveinn H. | |
dc.contributor.author | Schalij-Delfos, Nicoline E. | |
dc.contributor.author | Stefánsson, Einar | |
dc.date.accessioned | 2018-01-11T17:15:40Z | |
dc.date.available | 2018-01-11T17:15:40Z | |
dc.date.issued | 2017-12 | |
dc.date.submitted | 2018 | |
dc.identifier.citation | Fundus imaging in newborn children with wide-field scanning laser ophthalmoscope 2017, 95 (8):842 Acta Ophthalmologica | en |
dc.identifier.issn | 1755375X | |
dc.identifier.doi | 10.1111/aos.13453 | |
dc.identifier.uri | http://hdl.handle.net/2336/620431 | |
dc.description | To access publisher's full text version of this article click on the hyperlink below | en |
dc.description.abstract | PURPOSE: Current fundus imaging in newborn babies requires mydriatics, eye specula and corneal contact. We propose that a scanning laser ophthalmoscope (SLO) allows ultra wide-field imaging with reduced stress for the child. METHODS: This prospective observational single centre study was conducted in Landspítali, University Hospital, Reykjavik, Iceland. In this study, a noncontact wide-field SLO (Optomap 200Tx) was used to image the retina in healthy full-term newborns without the use of mydriatics or eye specula. The child was held by one of the parents, while one of the researchers supported the child's head in front of the SLO camera for alignment and opened the eye with either a finger or a cotton tip. RESULTS: Fifty-nine participants were recruited (34 females). The mean age was 16 days, and the mean gestational age was 40 ± 1 weeks at the time of imaging. Ultra-wide-field (200°) images were obtained of 44 participants. Twenty-seven participants (61%) had at least one ultra wide-field image with the optic disc and vessel segments in all quadrants of the fundus visible and in focus. No retinal pathology was found in the participants with the exception of one participant with small retinal haemorrhages. CONCLUSION: Scanning laser ophthalmoscope (SLO) ultra-wide-field fundus imaging is feasible in healthy full-term newborns without corneal contact, eye speculum or mydriatics. This approach could be an improvement for retinal imaging in newborn infants. Eye movement of the infant, whether asleep or awake, influenced which part of the fundus was captured, but focus and image quality were generally good. | |
dc.description.sponsorship | ODAS foundation (Den Hoorn, The Netherlands) Icelandic Center for Research (Rannis) University of Iceland Research Fund Landspitali University Hospital Research Fund Helga Jonsdottir and Sigurlidi Kristjansson Memorial Fund | en |
dc.language.iso | en | en |
dc.publisher | Wiley | en |
dc.relation.url | http://doi.wiley.com/10.1111/aos.13453 | en |
dc.rights | Archived with thanks to Acta Ophthalmologica | en |
dc.subject | Augnbotnar | en |
dc.subject | Nýburar | en |
dc.subject | Myndgreining (læknisfræði) | en |
dc.subject | OPH12 | en |
dc.subject | PTT12 | en |
dc.subject | PER12 | en |
dc.subject.mesh | Fundus Oculi | en |
dc.subject.mesh | Infant, Newborn | en |
dc.subject.mesh | Ophthalmoscopes | en |
dc.subject.mesh | diagnostic imaging | en |
dc.subject.mesh | Macula Lutea | en |
dc.title | Fundus imaging in newborn children with wide-field scanning laser ophthalmoscope | en |
dc.type | Article | en |
dc.contributor.department | [ 1 ] Univ Iceland, Landspitali Univ Hosp, Dept Ophthalmol, Reykjavik, Iceland Show more [ 2 ] Oslo Univ Hosp, Dept Ophthalmol, Oslo, Norway Show more [ 3 ] Leiden Univ, Leiden Univ Med Ctr, Dept Ophthalmol, Leiden, Netherlands | en |
dc.identifier.journal | Acta Ophthalmologica | en |
dc.rights.access | National Consortium - Landsaðgangur | en |
dc.contributor.institution | Department of Ophthalmology; Landspítali University Hospital; University of Iceland; Reykjavik Iceland | |
dc.contributor.institution | Department of Ophthalmology; Leiden University Medical Center; University of Leiden; Leiden Netherlands | |
dc.contributor.institution | Department of Ophthalmology; Landspítali University Hospital; University of Iceland; Reykjavik Iceland | |
dc.contributor.institution | Department of Ophthalmology; Landspítali University Hospital; University of Iceland; Reykjavik Iceland | |
dc.contributor.institution | Department of Ophthalmology; Leiden University Medical Center; University of Leiden; Leiden Netherlands | |
dc.contributor.institution | Department of Ophthalmology; Landspítali University Hospital; University of Iceland; Reykjavik Iceland | |
dc.departmentcode | OPH12, PTT12, PER12 | |
html.description.abstract | PURPOSE: Current fundus imaging in newborn babies requires mydriatics, eye specula and corneal contact. We propose that a scanning laser ophthalmoscope (SLO) allows ultra wide-field imaging with reduced stress for the child. METHODS: This prospective observational single centre study was conducted in Landspítali, University Hospital, Reykjavik, Iceland. In this study, a noncontact wide-field SLO (Optomap 200Tx) was used to image the retina in healthy full-term newborns without the use of mydriatics or eye specula. The child was held by one of the parents, while one of the researchers supported the child's head in front of the SLO camera for alignment and opened the eye with either a finger or a cotton tip. RESULTS: Fifty-nine participants were recruited (34 females). The mean age was 16 days, and the mean gestational age was 40 ± 1 weeks at the time of imaging. Ultra-wide-field (200°) images were obtained of 44 participants. Twenty-seven participants (61%) had at least one ultra wide-field image with the optic disc and vessel segments in all quadrants of the fundus visible and in focus. No retinal pathology was found in the participants with the exception of one participant with small retinal haemorrhages. CONCLUSION: Scanning laser ophthalmoscope (SLO) ultra-wide-field fundus imaging is feasible in healthy full-term newborns without corneal contact, eye speculum or mydriatics. This approach could be an improvement for retinal imaging in newborn infants. Eye movement of the infant, whether asleep or awake, influenced which part of the fundus was captured, but focus and image quality were generally good. |